The chemical maintenance of electrophoresis production


article source:Yiwo Content Management System Release time : 2017-06-29 views:503
In order to let the former processing system designed to meet the required quality, must be careful of slot liquid chemical control and maintenance. Must be set up and control the scope of special operation parameters. The need to control the special parameters include the processing time (velocity), temperature, chemical concentration, pH, and total dissolved solids, etc.
Degreasing process
Each work shift at the beginning, middle and quitting time check slot liquid chemical concentration, temperature and pressure. Adjusted as necessary.
Washing process
Each work shift to total dissolved solids (TDS) and conductance for inspection three times. Do not allow the TDS and pH value is larger than that of raw water these values have much higher. Adjust the overflow of water will help control the leaching water of water quality. If necessary, must be regularly in tank and wash tank ?